Skip to main content
3.21.46.78

The Use of Near-Infrared and Microwave Resonance Sensing to Monitor a Continuous Roller Compaction Process

By Austin, John; Gupta, Anshu; Mcdonnell, Ryan; Reklaitis, Gintaras V.; Harris, Michael T

Published on CMKC

Abstract

Roller compaction is commonly used in the pharmaceutical and nutraceutical industries to increase and narrow the size distribution of a particulate material, making it easier to process. Both the moisture content of the material and the density of the roller compacted ribbon affect the uniformity and physical properties of the resultant granules. Without process analytical technologies, these parameters cannot be determined on-line or in real time. In this study, the more commonly used near-infrared (NIR) spectroscopy was compared and contrasted with microwave resonance for the determination of roller-compacted ribbons' envelope density and moisture content. Results indicate that microwave resonance can offer improved accuracy, robustness, and ease-of-use compared with NIR spectroscopy for these property measurements.

Journal

Journal of Pharmaceutical Sciences. Volume 102, 2013, 1895-1904

DOI

10.1002/jps.23536

Type of publication

Peer-reviewed journal

Affiliations

  • Purdue University

Article Classification

Research article

Classification Areas

  • PAT
  • Oral solid dose

Tags