Skip to main content
18.97.14.83

The use of rheology to elucidate the granulation mechanisms of a miscible and immiscible system during continuous twin-screw melt granulation

By Monteyne, Tinne; Heeze, Liza; Mortier, Severine Therese F. C.; Oldorp, Klaus; Nopens, Ingmar; Remon, Jean-Paul; Vervaet, Chris; De Beer, Thomas

Published on

Abstract

Twin-screw hot melt granulation (TS HMG) is a valuable, but still unexplored alternative to granulate temperature and moisture sensitive drugs in a continuous way. Recently, the material behavior of an immiscible drug-binder blend during TS HMG was unraveled by using a rheometer and differential scanning calorimetry (DSC). Additionally, vibrational spectroscopic techniques proved the link between TS HMG and rheology since equal interactions at molecular level did occur in both processes. This allowed to use a rheometer to gain knowledge of the material behavior during hot melt processing of an immiscible drug-binder blend. However, miscibility of a drug-binder formulation and drug-binder interactions appear to influence the rheological properties and, hence conceivably also the granulation mechanism. The aim of this Research Article was to examine if the TS HMG process of a miscible formulation system is comparable with the mechanism of an immiscible system and to evaluate whether rheology still serves as a useful tool to understand and optimize the hot melt granulation (HMG) process. The executed Research Article (thermal analysis, rheological parameters and spectroscopic data) demonstrated the occurrence of a high and broad tan(delta) curve without a loss peak during the rheological temperature ramp which implies a higher material deformability without movement of the softened single polymer chains. Spectroscopic analysis revealed drug-polymer interactions which constrain the polymer to flow independently. As a result, the binder distribution step, which generally follows the immersion step, was hindered. This insight assisted the understanding of the granule properties. Inhomogeneous granules were produced due to large initial nuclei or adhesion of multiple smaller nuclei. Consequently, a higher granulation temperature was required in order to get the binder more homogeneously distributed within the granules.

Journal

International Journal of Pharmaceutics. Volume 510, 2016, 271-284

DOI

10.1016/j.ijpharm.2016.06.055

Type of publication

Peer-reviewed journal

Affiliations

  • Ghent University

Article Classification

Research article

Classification Areas

  • Oral solid dose
  • Process Control

Tags