Skip to main content
Join CMKC members for a complimentary virtual event on December 10, 11am ET: CM MythBusters: https://bit.ly/3YXJynA. This is a fantastic opportunity to connect, collaborate, and debunk common myths about continuous manufacturing!
18.188.113.189

Design and Evaluation of Topical Diclofenac Sodium Gel Using Hot Melt Extrusion Technology as a Continuous Manufacturing Process with Kolliphor® P407

By Pawar, Jaywant; Narkhede, Rajkiran; Amin, Purnima; Tawde, Vaishali

Published on

Abstract

The aim of the present context was to develop and evaluate a Kolliphor® P407-based transdermal gel formulation of diclofenac sodium by hot melt extrusion (HME) technology; central composite design was used to optimize the formulation process. In this study, we have explored first time ever HME as an industrially feasible and continuous manufacturing technology for the manufacturing of gel formulation using Kolliphor® P407 and Kollisolv® PEG400 as a gel base. Diclofenac sodium was used as a model drug. The HME parameters such as feeding rate, screw speed, and barrel temperature were crucial for the semisolid product development, and were optimized after preliminary trials. For the processing of the gel formulation by HME, a modified screw design was used to obtain a uniform product. The obtained product was evaluated for physicochemical characterization such as differential scanning calorimetry (DSC), X-ray diffraction (XRD), pH measurement, rheology, surface tension, and texture profile analysis. Moreover, it was analyzed for general appearance, spreadibility, surface morphology, and drug content. The optimized gel formulation showed homogeneity and transparent film when applied on a glass slide under microscope, pH was 7.02 and uniform drug content of 100.04 ± 2.74 (SD = 3). The DSC and XRD analysis of the HME gel formulation showed complete melting of crystalline API into an amorphous form. The Kolliphor® P407 and Kollisolv® PEG400 formed excellent gel formulation using HME with consistent viscoelastic properties of the product. An improved drug release was found for the HME gel, which showed a 100% drug release than that of a marketed product which showed only 88% of drug release at the end of 12 h. The Flux value of the HME gel was 106 than that of a marketed formulation, which showed only about 60 value, inferring a significant difference (P < 0.05) at the end of 1 h. This study demonstrates a novel application of the hot melt extrusion process for manufacturing of topical semisolid products.

Journal

AAPS PharmSciTech. Volume 18, 2017, 2303-2315

DOI

10.1208/s12249-017-0713-5

Type of publication

Peer-reviewed journal

Affiliations

  • BASF India Ltd
  • Institute of Chemical Technology, Mumbai

Article Classification

Research Article

Classification Areas

  • Process Analytical Technologies

Tags