CONTROL OF THE CONTINUOUS VIBRATION FLUIDIZED-BED DRYING BY MEASUREMENT OF THE RELATIVE GRANULATION HUMIDITY
Category
Published on CMKC
Abstract
This article describes a method to measure the relative granulation humidity in the pharmaceutical production. The method is employed as on-line process controll for monitoring the continuous fluidized-bed drying process. The dryer settings are adjusted according to the relative humidity readings. The method is used to optimize the drying process with respect to reproducability of residue moisture content and energy consumption.
Journal
Pharmaceutical Industry. Volume 54, 4, 1992, 366-369
Type of publication
Peer-reviewed journal
Affiliations
- Sandoz AG
Article Classification
Research article
Classification Areas
- Oral solid dose