In-line monitoring of low drug concentration of flowing powders in a new sampler device

By Sierra-Vega, Nobel O; Méndez, Rafael; Martínez-Cartagena, Pedro; Alvarado-Hernández, Bárbara B; Romañach, Rodolfo J.

Published on

Abstract

A novel sampler device for flowing powders was tested to quantify drug concentrations as low as 0.76% w/w in pharmaceutical powder blends. The sampler device was developed based on the powder flow behavior within a tablet press feed frame, following the principles laid down in the Theory of Sampling. Two Near-Infrared (NIR) spectroscopic calibration models were developed with powder blends that varied from 0.52 to 2.52% w/w and 1.51–4.52% w/w. The calibration models were able to determine caffeine concentration in test set blends with root mean square error of predictions and bias below 0.1% w/w. Samples were collected from the sampler device and analyzed by ultraviolet-visible (UV–Vis) to determine the caffeine concentration. A high agreement between the in-line NIR predictions and the sampled UV–Vis results was found. The paddle wheel speed in the sampler can be varied up to ±10% without affecting NIR predictions; however, the models did not respond adequately to a 25% increase in this speed. Variographic analysis showed that the sampler device may quantify low drug concentrations with nugget effects below 0.0050 (%w/w)2. This study demonstrate that the sampler device may handle throughputs up to 45 kg/h, without significantly affecting the physical properties of powder blends.

Journal

International Journal of Pharmaceutics. Volume 538, 2020, 119358

DOI

10.1016/j.ijpharm.2020.119358

Type of publication

Peer-reviewed journal

Affiliations

  • University of Puerto Rico at Mayagüez

Article Classification

Research article

Classification Areas

  • PAT
  • Oral solid dose

Tags