Skip to main content
Join CMKC members for a complimentary virtual event on December 10, 11am ET: CM MythBusters: https://bit.ly/3YXJynA. This is a fantastic opportunity to connect, collaborate, and debunk common myths about continuous manufacturing!
3.133.152.189

Tags: Principal component analysis (PCA) / Partial least square analysis (PLSA)

Peer-reviewed journal (1-1 of 1)

  1. Process analytical technology in continuous manufacturing of a commercial pharmaceutical product

    09 Jun 2023 | Contributor(s):: Vargas, Jenny, Nielsen, Sarah, Cárdenas, Vanessa, Gonzalez, Anthony, Aymat, Efrain, Almodovar, Elvin, Classe, Gustavo, Colón, Yleana, Sanchez, Eric, Romañach, Rodolfo

    The implementation of process analytical technology and continuous manufacturing at an FDA approved commercial manufacturing site is described. In this direct compaction process the blends produced were monitored with a Near Infrared (NIR) spectroscopic calibration model developed with partial...