Skip to main content
18.226.181.14

Tags: monitoring

All Categories (1-3 of 3)

  1. Near infrared spectroscopic calibration models for real time monitoring of powder density

    Contributor(s):: Román-Ospino, Andrés, Singh, Ravendra, Ierapetritoua, Marianthi, Ramachandrana, Rohit, Mendez, Rafael, Ortega-Zuñiga, Carlos, Muzzio, Fernando, Romañach, Rodolfo

    Near infrared spectroscopic (NIRS) calibration models for real time prediction of powder density (tap, bulk and consolidated) were developed for a pharmaceutical formulation. Powder density is a critical property in the manufacturing of solid oral dosages, related to critical quality attributes...

  2. Integrated continuous manufacturing in pharmaceutical industry: current eolutionary steps toward revolutionary future

    Contributor(s):: Nada A Helal, Ola Elnoweam, Heba Abdullah Eassa, Ahmed M Amer, Mohamed Ashraf Eltokhy, Mohamed A Helal, Heba A Fayyaz, Mohamed Ismail Nonou

    Continuous manufacturing (CM) has the potential to provide pharmaceutical products with better quality, improved yield and with reduced cost and time. Moreover, ease of scale-up, small manufacturing footprint and on-line/in-line monitoring and control of the process are other merits for CM....

  3. Application of the quantitative detection of a change in concentration of magnesium stearate in a feeder tube of tableting manufacture by real-time near-infrared spectroscopy

    Contributor(s):: Sasakura, D., Nakayama, K., Chikuma, T.

    Process analytical technology is important for the analysis and control of manufacturing processes. Near-infrared spectroscopy is widely used in various process analytical technologies for the analysis of the chemical components of solid dosage forms. Lubrication is an important process carried...