Skip to main content
Join CMKC members for a complimentary virtual event on December 10, 11am ET: CM MythBusters: https://bit.ly/3YXJynA. This is a fantastic opportunity to connect, collaborate, and debunk common myths about continuous manufacturing!
18.191.93.18

A Continuous Operation Concept for a Rotary Tablet Press Using Mass Flow Operating Points

By Martinetz, Michael Christian; Rehrl, Jakob Aigner, Isabella Sacher, Stephan; Khinast, Johannes

Published on

Abstract

Abstract In a continuous pharmaceutical manufacturing line the rotary tablet press was viewed as the master of control concept and defined the mass flow through the entire process. According to a conventional control concept, missing mass flow from an upstream unit operation leads to a shutdown of the tablet press. Various operating scenarios were simulated and the influence of turret speed on the tablet properties was experimentally investigated. Changes in the turret speed alter the critical process parameters dwell time and die filling time. Their influence was evaluated using two model formulations with different compaction behavior.

Journal

Chemie Ingenieur Technik. Volume 89, 8, 2017, 1006-1016

DOI

10.1002/cite.201700017

Type of publication

Peer-reviewed journal

Affiliations

  • Research Center Pharmaceutical Engineering GmbH
  • Graz University of Technology

Article Classification

Research Article

Classification Areas

  • Control

Tags