Skip to main content
18.217.150.88

Resources: All

Find a resource
  1. nearinfraredspectroscopy x
  2. continuousprocessing x
  3. continuouspharmaceuticalmanufacturing x
  1. Critical review on the role of excipient properties in pharmaceutical powder-to-tablet continuous manufacturing

    13 Aug 2024 | Peer-reviewed journal | Contributor(s): Sara Fathollahi, Pauline H. M. Janssen, Bastiaan H. J. Dickhoff, Henderik W. Frijlink

    The pharmaceutical industry is gradually changing batch-wise manufacturing processes to continuous manufacturing processes, due to the advantages it has to offer. The final product quality and process efficiency of continuous manufacturing processes is among others impacted by the properties of...

  2. Process intensification of pharmaceutical powder blending at commercial throughputs by utilizing semi-continuous mini-blending

    13 Aug 2024 | Peer-reviewed journal | Contributor(s): Maarten Jaspers, Florian Tegel, Timo P. Roelofs, Fabian Starsich, Yunfei Li Song, Bernhard Meir, Richard Elkes, Bastiaan H.J. Dickhoff

    Process intensification involves the miniaturization of equipment while retaining process throughput and performance. The pharmaceutical industry can benefit from this approach especially during drug product development, where the availability of active pharmaceutical ingredients (API) is often...

  3. The Use of a Closed Feed Frame for the Development of Near-Infrared Spectroscopic Calibration Model to Determine Drug Concentration

    23 Jul 2024 | Peer-reviewed journal | Contributor(s): Movilla-Meza, Nathaly A., Sierra-Vega, Nobel O., Alvarado-Hernández, Bárbara B., Méndez, Rafael, Romañach, Rodolfo J.

    Purpose: This study evaluates the use of the closed feed frame as a material sparing approach to develop near-infrared (NIR) spectroscopic calibration models for monitoring blend uniformity. The effect of shear induced by recirculation on NIR spectra was also studied. Methods: Calibration models...

  4. Cleaning of direct compression continuous manufacturing equipment through displacement of API residues by excipients

    23 Jul 2024 | Peer-reviewed journal | Contributor(s): Patel, Dhavalkumar S, Méndez, Rafael, Romañach, Rodolfo J

    This feasibility study evaluates a cleaning process designed to avoid the use of detergents and reduce operator exposure to the active pharmaceutical ingredient (API). The continuous manufacturing equipment was cleaned using excipients to displace ibuprofen residues from the system. The cleaning...

  5. Videometric mass flow control: A new method for real-time measurement and feedback control of powder micro-feeding based on image analysis

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Madarasz, L, Kote, AGyurkes, M, Farkas, A, Hambalko, B, Pataki, H, Fulop, G, Marosi, G, Lengyel, L, Casian, T, Csorba, K, Nagy, ZK

    The present paper reports the first monitoring and control of ultra-low dose powder feeding using a camera image-based mass flow measurement system. Caffeine was fed via a single-screw microfeeder as a model active pharmaceutical ingredient (API). The mass, mass flow and sizes of the particles...

  6. Using a material property library to find surrogate materials for pharmaceutical process development

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Escotet-Espinoza, MS, Moghtadernejad, SScicolone, J, Wang, YF, Pereira, G, Schafer, E, Vigh, T, Klingeleers, D, Ierapetritou, M, Muzzio, FJ

    Material properties are known to have a significant impact on pharmaceutical manufacturing performance, particularly for solid product processes. Evaluating the performance of a specific material, for example an active pharmaceutical ingredient or excipient, is critical during development stages...

  7. Using residence time distribution in pharmaceutical solid dose manufacturing–A critical review

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Bhalode, Pooja, Tian, Huayu Gupta, Shashwat Razavi, Sonia M Roman-Ospino, Andres Talebian, Shahrzad Singh, Ravendra Scicolone, James V Muzzio, Fernando J, Ierapetritou, Marianthi

    While continuous manufacturing (CM) of pharmaceutical solid-based drug products has been shown to be advantageous for improving the product quality and process efficiency in alignment with FDA’s support of the quality-by-design paradigm (Lee, 2015; Ierapetritou et al., 2016; Plumb, 2005; Schaber,...

  8. Using Residence Time Distributions (RTDs) to Address the Traceability of Raw Materials in Continuous Pharmaceutical Manufacturing

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Engisch, William, Muzzio, Fernando

    Continuous processing in pharmaceutical manufacturing is a relatively new approach that has generated significant attention. While it has been used for decades in other industries, showing significant advantages, the pharmaceutical industry has been slow in its adoption of continuous processing,...

  9. The synthesis of active pharmaceutical ingredients (APIs) using continuous flow chemistry

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Baumann, M, Baxendale, IR

    The implementation of continuous flow processing as a key enabling technology has transformed the way we conduct chemistry and has expanded our synthetic capabilities. As a result many new preparative routes have been designed towards commercially relevant drug compounds achieving more efficient...

  10. The Use of PAT and Off-line Methods for Monitoring of Roller Compacted Ribbon and Granule Properties with a View to Continuous Processing

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): McAuliffe M.A.P., Omahony G.E., Blackshields C.A., Collins J.A., Egan D.P., Kiernan L., Oneill E., Lenihan S., Walker G.M., Crean A.M.

    Real-time process monitoring using process analytical technology (PAT) tools can augment process understanding, enable improved process control, and hence facilitate the production of high-quality pharmaceutical products. While beneficial for batch processes, the availability of PAT tools to...

  11. The Use of Near-Infrared and Microwave Resonance Sensing to Monitor a Continuous Roller Compaction Process

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Austin, John, Gupta, Anshu, Mcdonnell, Ryan, Reklaitis, Gintaras V., Harris, Michael T

    Roller compaction is commonly used in the pharmaceutical and nutraceutical industries to increase and narrow the size distribution of a particulate material, making it easier to process. Both the moisture content of the material and the density of the roller compacted ribbon affect the uniformity...

  12. Supervisory Control System for Monitoring a Pharmaceutical Hot Melt Extrusion Process

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Markl, Daniel, Wahl, Patrick R, Menezes, José C, Koller, Daniel M, Kavsek, Barbara, Francois, Kjell, Roblegg, Evaa, Khinast, Johannes G.

    Continuous pharmaceutical manufacturing processes are of increased industrial interest and require uni- and multivariate Process Analytical Technology (PAT) data from different unit operations to be aligned and explored within the Quality by Design (QbD) context. Real-time pharmaceutical process...

  13. Small-Volume Continuous Manufacturing of Merestinib. Part 1. Process Development and Demonstration

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Cole, KP, Reizman, BJHess, M, Groh, JM, Laurila, ME, Cope, RF, Campbell, BM, Forst, MB, Burt, JL, Maloney, TD, Johnson, MD, Mitchell, D, Polster, CS, Mitra, AW, Boukerche, M, Conder, EW, Braden, TM, Miller, RD, Heller, MR, Phillips, JL, Howell, JR

    Development of a small volume continuous process that used a combination of batch and flow unit operations to manufacture the small molecule oncolytic candidate merestinib is described. Continuous processing was enabled following the identification and development of suitable chemical...

  14. Small-Volume Continuous Manufacturing of Merestinib. Part 2.Technology Transfer and cGMP Manufacturing

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Reizman, Brandon J., Hess, Molly, Burt, Justin L., Maloney, Todd D., Johnson, Martin D., Laurila, Michael E., Cope, Richard F., Luciani, Carla V., Buser, Jonas Y., Campbell, Bradley M., Forst, Mindy B., Mitchell, David, Braden, Timothy M., Lippelt, Christopher K., Boukerche, Moussa, Starkey, Derek R., Miller, Richard D., Chen, Jing, Sun, Baoquan, Kwok, Martin, Zhang, Xin, Tadayon, Sam, Huang, Ping

    Technology transfer of a small volume continuous (SVC) process and Current Good Manufacturing Practices (cGMP) manufacturing of merestinib are described. A hybrid batch-SVC campaign was completed at a contract manufacturing organization under cGMP. The decision process by which unit operations...

  15. Simplified end-to-end continuous manufacturing by feeding API suspensions in twin-screw wet granulation

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Schmidt, A, de, Waard, HMoll, KP, Kleinebudde, P, Krumme, M

    This study focussed on investigating the coupling of continuous manufacturing of drug substance and continuous manufacture of drug product. An important step in such an integrated end-to-end continuous manufacturing was envisioned by dosing the API as suspension into a twin-screw wet granulation...

  16. Simulation-Based Design of an Efficient Control System for the Continuous Purification and Processing of Active Pharmaceutical Ingredients

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Sen, M, Singh, R, Ramachandran, R

    In this study, an efficient system-wide controlsystem has been designed for the integrated continuous purification and processing of the active pharmaceutical ingredient (API). The control strategy is based on the regulatory PID controller which is most widely used in the manufacturing industry...

  17. Robustness of a continuous direct compression line against disturbances in feeding

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Karttunen A.-P., Poms J., Sacher S., Sparén A., Ruiz Samblás C., Fransson M., Martin De Juan L., Remmelgas J., Wikström H., Hsiao W.-K., Folestad S., Korhonen O.

    The aim of the current study was to characterize the robustness of an integrated continuous direct compression (CDC) line against disturbances from feeding, i.e. impulses of API and short step disturbances. These disturbances mimicked typical variations that can be encountered during long-term...

  18. Residence Time Distribution (RTD)-Based Control System for Continuous Pharmaceutical Manufacturing Process

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Bhaskar, Aparajith, Singh, Ravendra

  19. Real-Time Monitoring of Powder Mass Flowrates for Plant-Wide Control of a Continuous Direct Compaction Tablet Manufacturing Process

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Huang, Yan-Shu, Medina-González, Sergio Straiton, Benjamin Keller, Joshua, Marashdeh, Qussai, Gonzalez, Marcial, Nagy, Zoltan, Reklaitis, Gintaras V.

    While measurement and monitoring of powder/particulate mass flow rate are not essential to the execution of traditional batch pharmaceutical tablet manufacturing, in continuous operation, it is an important additional critical process parameter. It has a key role both in establishing that the...

  20. Real-time monitoring of drug concentration in a continuous powder mixing process using NIR spectroscopy

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Vanarase, Aditya, Alcalà, Manel, Jerez-Rozo, Jackeline, Muzzio, Fernando, Romañach, Rodolfo

    A non-destructive NIR spectroscopic method was used to acquire on-line spectra of a continuous mixing process, and evaluate the performance of this novel system. Partial least squares (PLS) calibration models were developed and used for real-time determination of active ingredient concentration...

  21. Real-time process monitoring in a semi-continuous fluid-bed dryer - microwave resonance technology versus near-infrared spectroscopy

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Peters, Johanna, Teske, Andreas, Taute, Wolfgang, Döscher, Claas, Höft, Michael, Knöchel, Reinhard, Breitkreutz, Jörg

    The trend towards continuous manufacturing in the pharmaceutical industry is associated with an increasing demand for advanced control strategies. It is a mandatory requirement to obtain reliable real-time information on critical quality attributes (CQA) during every process step as the decision...

  22. Real-Time Quantification of Low-Dose Cohesive Formulations within a Sampling Interface for Flowing Powders

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Sierra-Vega, Nobel. O., Romañach, Rodolfo J., Mendez, Rafael

    This study investigates the performance of a sampling interface for monitoring cohesive, flowing powder formulations with Hausner's Ratio and Carr's Index higher than 1.5 and 35%, respectively. The sampler device was operated in combination with near-infrared (NIR) spectroscopy to quantify...

  23. Real-time monitoring of particle size distribution in a continuous granulation and drying process by near infrared spectroscopy

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Pauli, V, Roggo, YKleinebudde, P, Krumme, M

    In continuous granulation, it can be important to control granules particle size distribution (PSD), as it may affect final product quality. Near infrared spectroscopy (NIRS) is already a routine analytical procedure within pharmaceutical continuous manufacturing for the in-line analysis of...

  24. Quality Risk Assessment and Mitigation of Pharmaceutical Continuous Manufacturing Using Flowsheet Modeling Approach

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Tian, Geng;, Koolivand, Abdollah, Arden, Nilou S., Lee, Sau, O'Connor, Thomas F.

    Integrated flowsheet modeling is an engineering approach that can provide a framework for understanding the impact of process dynamics on drug quality and associated risks during production, thereby facilitating the development of robust continuous processes. In this investigation, flowsheet...

  25. Process optimization for continuous extrusion wet granulation

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Tan, L, Carella, AJ, Ren, YK, Lo, JB

    Three granulating binders in high drug-load acetaminophen blends were evaluated using high shear granulation and extrusion granulation. A polymethacrylate binder enhanced tablet tensile strength with rapid disintegration in simulated gastric fluid, whereas polyvinylpyrrolidone and hydroxypropyl...