Skip to main content
Join CMKC members for a complimentary virtual event on December 10, 11am ET: CM MythBusters: https://bit.ly/3YXJynA. This is a fantastic opportunity to connect, collaborate, and debunk common myths about continuous manufacturing!
13.58.201.240

Resources: All

Find a resource
  1. nearinfraredspectroscopy x
  2. oraldoses x
  3. continuousprocessing x
  1. Critical review on the role of excipient properties in pharmaceutical powder-to-tablet continuous manufacturing

    13 Aug 2024 | Peer-reviewed journal | Contributor(s): Sara Fathollahi, Pauline H. M. Janssen, Bastiaan H. J. Dickhoff, Henderik W. Frijlink

    The pharmaceutical industry is gradually changing batch-wise manufacturing processes to continuous manufacturing processes, due to the advantages it has to offer. The final product quality and process efficiency of continuous manufacturing processes is among others impacted by the properties of...

  2. Process intensification of pharmaceutical powder blending at commercial throughputs by utilizing semi-continuous mini-blending

    13 Aug 2024 | Peer-reviewed journal | Contributor(s): Maarten Jaspers, Florian Tegel, Timo P. Roelofs, Fabian Starsich, Yunfei Li Song, Bernhard Meir, Richard Elkes, Bastiaan H.J. Dickhoff

    Process intensification involves the miniaturization of equipment while retaining process throughput and performance. The pharmaceutical industry can benefit from this approach especially during drug product development, where the availability of active pharmaceutical ingredients (API) is often...

  3. The Use of a Closed Feed Frame for the Development of Near-Infrared Spectroscopic Calibration Model to Determine Drug Concentration

    23 Jul 2024 | Peer-reviewed journal | Contributor(s): Movilla-Meza, Nathaly A., Sierra-Vega, Nobel O., Alvarado-Hernández, Bárbara B., Méndez, Rafael, Romañach, Rodolfo J.

    Purpose: This study evaluates the use of the closed feed frame as a material sparing approach to develop near-infrared (NIR) spectroscopic calibration models for monitoring blend uniformity. The effect of shear induced by recirculation on NIR spectra was also studied. Methods: Calibration models...

  4. Cleaning of direct compression continuous manufacturing equipment through displacement of API residues by excipients

    23 Jul 2024 | Peer-reviewed journal | Contributor(s): Patel, Dhavalkumar S, Méndez, Rafael, Romañach, Rodolfo J

    This feasibility study evaluates a cleaning process designed to avoid the use of detergents and reduce operator exposure to the active pharmaceutical ingredient (API). The continuous manufacturing equipment was cleaned using excipients to displace ibuprofen residues from the system. The cleaning...

  5. Using Residence Time Distributions (RTDs) to Address the Traceability of Raw Materials in Continuous Pharmaceutical Manufacturing

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Engisch, William, Muzzio, Fernando

    Continuous processing in pharmaceutical manufacturing is a relatively new approach that has generated significant attention. While it has been used for decades in other industries, showing significant advantages, the pharmaceutical industry has been slow in its adoption of continuous processing,...

  6. Using residence time distribution in pharmaceutical solid dose manufacturing–A critical review

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Bhalode, Pooja, Tian, Huayu Gupta, Shashwat Razavi, Sonia M Roman-Ospino, Andres Talebian, Shahrzad Singh, Ravendra Scicolone, James V Muzzio, Fernando J, Ierapetritou, Marianthi

    While continuous manufacturing (CM) of pharmaceutical solid-based drug products has been shown to be advantageous for improving the product quality and process efficiency in alignment with FDA’s support of the quality-by-design paradigm (Lee, 2015; Ierapetritou et al., 2016; Plumb, 2005; Schaber,...

  7. The synthesis of active pharmaceutical ingredients (APIs) using continuous flow chemistry

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Baumann, M, Baxendale, IR

    The implementation of continuous flow processing as a key enabling technology has transformed the way we conduct chemistry and has expanded our synthetic capabilities. As a result many new preparative routes have been designed towards commercially relevant drug compounds achieving more efficient...

  8. The Use of PAT and Off-line Methods for Monitoring of Roller Compacted Ribbon and Granule Properties with a View to Continuous Processing

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): McAuliffe M.A.P., Omahony G.E., Blackshields C.A., Collins J.A., Egan D.P., Kiernan L., Oneill E., Lenihan S., Walker G.M., Crean A.M.

    Real-time process monitoring using process analytical technology (PAT) tools can augment process understanding, enable improved process control, and hence facilitate the production of high-quality pharmaceutical products. While beneficial for batch processes, the availability of PAT tools to...

  9. The Use of Near-Infrared and Microwave Resonance Sensing to Monitor a Continuous Roller Compaction Process

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Austin, John, Gupta, Anshu, Mcdonnell, Ryan, Reklaitis, Gintaras V., Harris, Michael T

    Roller compaction is commonly used in the pharmaceutical and nutraceutical industries to increase and narrow the size distribution of a particulate material, making it easier to process. Both the moisture content of the material and the density of the roller compacted ribbon affect the uniformity...

  10. The scope of PAT in real-time advanced control of tablet quality

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Singh, Ravendra, Ierapetritou, Marianthi, Ramachandran, Rohit

    Continuous pharmaceutical manufacturing together with process analytical technology (PAT) provides a suitable platform for automatic feed-forward/feed-back (FF/FB) control of the end product quality as desired by quality by design (QbD)-based efficient manufacturing. The precise control of the...

  11. Supervisory Control System for Monitoring a Pharmaceutical Hot Melt Extrusion Process

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Markl, Daniel, Wahl, Patrick R, Menezes, José C, Koller, Daniel M, Kavsek, Barbara, Francois, Kjell, Roblegg, Evaa, Khinast, Johannes G.

    Continuous pharmaceutical manufacturing processes are of increased industrial interest and require uni- and multivariate Process Analytical Technology (PAT) data from different unit operations to be aligned and explored within the Quality by Design (QbD) context. Real-time pharmaceutical process...

  12. Surrogate-based Optimization for Pharmaceutical Manufacturing Processes

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Wang, Zilong, Escotet-Espinoza, M Sebastian Singh, Ravendra, Ierapetritou, Marianthi

    The development of pharmaceutical manufacturing processes has been facilitated by recent advances in the process simulation area. However, since the simulations are usually complex and the analytical expressions of the model can be unknown, it is difficult to directly apply traditional...

  13. Small-Volume Continuous Manufacturing of Merestinib. Part 1. Process Development and Demonstration

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Cole, KP, Reizman, BJHess, M, Groh, JM, Laurila, ME, Cope, RF, Campbell, BM, Forst, MB, Burt, JL, Maloney, TD, Johnson, MD, Mitchell, D, Polster, CS, Mitra, AW, Boukerche, M, Conder, EW, Braden, TM, Miller, RD, Heller, MR, Phillips, JL, Howell, JR

    Development of a small volume continuous process that used a combination of batch and flow unit operations to manufacture the small molecule oncolytic candidate merestinib is described. Continuous processing was enabled following the identification and development of suitable chemical...

  14. Small-Volume Continuous Manufacturing of Merestinib. Part 2.Technology Transfer and cGMP Manufacturing

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Reizman, Brandon J., Hess, Molly, Burt, Justin L., Maloney, Todd D., Johnson, Martin D., Laurila, Michael E., Cope, Richard F., Luciani, Carla V., Buser, Jonas Y., Campbell, Bradley M., Forst, Mindy B., Mitchell, David, Braden, Timothy M., Lippelt, Christopher K., Boukerche, Moussa, Starkey, Derek R., Miller, Richard D., Chen, Jing, Sun, Baoquan, Kwok, Martin, Zhang, Xin, Tadayon, Sam, Huang, Ping

    Technology transfer of a small volume continuous (SVC) process and Current Good Manufacturing Practices (cGMP) manufacturing of merestinib are described. A hybrid batch-SVC campaign was completed at a contract manufacturing organization under cGMP. The decision process by which unit operations...

  15. Simulation-Based Design of an Efficient Control System for the Continuous Purification and Processing of Active Pharmaceutical Ingredients

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Sen, M, Singh, R, Ramachandran, R

    In this study, an efficient system-wide controlsystem has been designed for the integrated continuous purification and processing of the active pharmaceutical ingredient (API). The control strategy is based on the regulatory PID controller which is most widely used in the manufacturing industry...

  16. Simulation-Based Design of an Efficient Control System for the Continuous Purification and Processing of Active Pharmaceutical Ingredients

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Sen, M, Singh, R, Ramachandran, R

    In this study, an efficient system-wide controlsystem has been designed for the integrated continuous purification and processing of the active pharmaceutical ingredient (API). The control strategy is based on the regulatory PID controller which is most widely used in the manufacturing industry...

  17. Robustness of a continuous direct compression line against disturbances in feeding

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Karttunen A.-P., Poms J., Sacher S., Sparén A., Ruiz Samblás C., Fransson M., Martin De Juan L., Remmelgas J., Wikström H., Hsiao W.-K., Folestad S., Korhonen O.

    The aim of the current study was to characterize the robustness of an integrated continuous direct compression (CDC) line against disturbances from feeding, i.e. impulses of API and short step disturbances. These disturbances mimicked typical variations that can be encountered during long-term...

  18. Recent advances in integrated process analytical techniques, modeling, and control strategies to enable continuous biomanufacturing of monoclonal antibodies

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Chopda, Viki, Gyorgypal, Aron Yang, Ou Singh, Ravendra Ramachandran, Rohit Zhang, Haoran Tsilomelekis, George Chundawat, Shishir PS, Ierapetritou, Marianthi G

    Continuous bioprocessing is significantly changing the biological drugs (or biologics) manufacturing landscape by potentially improving product quality, process stability, and overall profitability, as was similarly seen during the adoption of advanced manufacturing processes for small molecule...

  19. Residence Time Distribution as a Traceability Method for Lot Changes in A Pharmaceutical Continuous Manufacturing System

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Sánchez-Paternina, Adriluz, Martínez-Cartagena, Pedro Li, Jingzhe Scicolone, James Singh, Ravendra Lugo, Yleana C Romañach, Rodolfo J Muzzio, Fernando J, Román-Ospino, Andrés D

    Residence time distribution (RTD) models were developed to track raw material lots and investigate batch transitions in a continuous manufacturing system. Two raw materials with similar physical properties (granular metformin and lactose) were identified via Principal Component Analysis (PCA)...

  20. Residence time distribution modelling and in line monitoring of drug concentration in a tablet press feed frame containing dead zones

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Tanimura, Shinji, Singh, Ravendra Román-Ospino, Andrés D, Ierapetritou, Marianthi

    The presence of a ‘significant dead zone’ in any continuous manufacturing equipment may affect the product quality and need to be investigated systematically. Dead zone will affect the residence time distribution (RTD) of continuous manufacturing and thus the mixing and product quality. Tablet...

  21. Real-Time Monitoring of Powder Mass Flowrates for Plant-Wide Control of a Continuous Direct Compaction Tablet Manufacturing Process

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Huang, Yan-Shu, Medina-González, Sergio Straiton, Benjamin Keller, Joshua, Marashdeh, Qussai, Gonzalez, Marcial, Nagy, Zoltan, Reklaitis, Gintaras V.

    While measurement and monitoring of powder/particulate mass flow rate are not essential to the execution of traditional batch pharmaceutical tablet manufacturing, in continuous operation, it is an important additional critical process parameter. It has a key role both in establishing that the...

  22. Real-time monitoring of drug concentration in a continuous powder mixing process using NIR spectroscopy

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Vanarase, Aditya, Alcalà, Manel, Jerez-Rozo, Jackeline, Muzzio, Fernando, Romañach, Rodolfo

    A non-destructive NIR spectroscopic method was used to acquire on-line spectra of a continuous mixing process, and evaluate the performance of this novel system. Partial least squares (PLS) calibration models were developed and used for real-time determination of active ingredient concentration...

  23. Real-time process monitoring in a semi-continuous fluid-bed dryer - microwave resonance technology versus near-infrared spectroscopy

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Peters, Johanna, Teske, Andreas, Taute, Wolfgang, Döscher, Claas, Höft, Michael, Knöchel, Reinhard, Breitkreutz, Jörg

    The trend towards continuous manufacturing in the pharmaceutical industry is associated with an increasing demand for advanced control strategies. It is a mandatory requirement to obtain reliable real-time information on critical quality attributes (CQA) during every process step as the decision...

  24. Real-Time Quantification of Low-Dose Cohesive Formulations within a Sampling Interface for Flowing Powders

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Sierra-Vega, Nobel. O., Romañach, Rodolfo J., Mendez, Rafael

    This study investigates the performance of a sampling interface for monitoring cohesive, flowing powder formulations with Hausner's Ratio and Carr's Index higher than 1.5 and 35%, respectively. The sampler device was operated in combination with near-infrared (NIR) spectroscopy to quantify...

  25. Real-time monitoring of particle size distribution in a continuous granulation and drying process by near infrared spectroscopy

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Pauli, V, Roggo, YKleinebudde, P, Krumme, M

    In continuous granulation, it can be important to control granules particle size distribution (PSD), as it may affect final product quality. Near infrared spectroscopy (NIRS) is already a routine analytical procedure within pharmaceutical continuous manufacturing for the in-line analysis of...