-
Delta-mannitol to enable continuous twin-screw granulation of a highly dosed, poorly compactable formulation
23 Jul 2024 | Contributor(s): Vanhoorne, V., Almey, R., De Beer, T., Vervaet, C.
In current study, it was investigated if the moisture-mediated polymorphic transition from δ- to β-mannitol during twin screw granulation (TSG) also took place in high drug loaded formulations and if the specific granule morphology associated with the polymorphic transition could enable tableting...
-
Control oriented modeling of twin-screw granulation in the ConsiGmaTM-25 production plant
09 Jul 2024 | Peer-reviewed journal | Contributor(s): Johannes Khinast, Martin Horn, Jakob Rehrl, Selma Celikovic, Johannes Poms
ConsiGmaTM-25 is a continuous production plant integrating a twin-screw granulation, fluid bed drying, granule conditioning, and a tableting unit. The particle size distribution (PSD), active pharmaceutical ingredient (API) content, and liquid content of wet granules after twin-screw...
-
Development of a Continuous Flow Grignard Reaction to Manufacture a Key Intermediate of Ipatasertib
25 Jun 2024 | Peer-reviewed journal | Contributor(s): Kaldre, Dainis, Stocker, Severin, Linder, David, Reymond, Helena, Schuster, Andreas, Lamerz, Jens, Hildbrand, Stefan, Püntener, Kurt, Berry, Malcolm, Sedelmeier, Jörg
This article outlines the development of a continuous flow process for the manufacture of a key intermediate of the active pharmaceutical ingredient ipatasertib for the treatment of metastatic castration-resistant prostate cancer and triple-negative metastatic breast cancer. The reaction sequence...
-
Innovation and Continuous Improvement in Pharmaceutical Manufacturing
28 Mar 2024 | Document | Contributor(s): Ajaz Hussain (Chairperson) Raafat Fahmy (CVM), William Bargo (CVM), Robert Coleman, Robert (ORA), Elise Murphy (ORA), Frank Holcombe Jr (CDER), Chris Watts (CDER), See Lam (CDER), Jon Clark (CDER), Christopher Joneckis (CBER), John Dietrick (CDER), Diana Kolaitis (ORA), Vilayat Sayeed (CDER), Mai Huynh (CVM), Norman Schmuff (CDER), Andrew Chang (CBER)
The PAT Team and Manufacturing Science Working Group Report: A Summary of Learning, Contributions and Proposed Next Steps for Moving towards the "Desired State" of Pharmaceutical Manufacturing in the 21st Century
-
A Perspective on Quality by Design: A Preclinical Opportunity
28 Mar 2024 | Document | Contributor(s): Ajaz S. Hussain
-
A Shared Vision for Pharmaceutical Development and Manufacturing in the 21st Century: Contributions of the PAT Initiative
28 Mar 2024 | Document | Contributor(s): Ajaz S. Hussain
-
The Subcommittee on Process Analytical Technologies (PAT): Closing Remarks
28 Mar 2024 | Document | Contributor(s): Ajaz S. Hussain
-
The Process Analytical Technology Initiative: PAT and the Pharmacopeias
28 Mar 2024 | Document | Contributor(s): Ajaz S. Hussain
The PAT Initiative A part of the Pharmaceutical Quality for the 21st Century Initiative PAT and the USP Opportunities for the USP to support the PAT Framework
-
Utilizing PAT to Monitor and Control Bulk Biotech Processes
27 Mar 2024 | Document | Contributor(s): Rick E. Cooley
1.What is and isn’t PAT? 2.Implementing PAT in Manufacturing: What does it take? 3.Characteristics of bulk, biotech API processes 4.Why PAT? 5.Review of PAT technologies utilized 6.PAT application examples
-
Continuous Manufacturing for Pharmaceutical Solid Dosage Forms (On-Demand)
31 Jan 2024 | Seminars | Contributor(s): Atul Dubey, Fernando Muzzio, Gerardo Callegari, Lucy L. Botros, Ravendra Singh, James Scicolone, Andres Roman, Sonia Modarres Razavi
Course Description: This self-paced curriculum contains fourteen self-paced modules and three recordings of live virtual education on Pharmaceutical Continuous Manufacturing (PCM). Learners will have access to the following: A recording of the introductory session covering topics such as...
-
Visualization and understanding of the granulation liquid mixing and distribution during continuous twin screw granulation using NIR chemical imaging
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Vercruysse, Jurgen, Toiviainen, Maunu, Fonteyne, Margot, Helkimo, Niko, Ketolainen, Jarkko, Juuti, Mikko, Delaet, Urbain, Van Assche, Ivo, Remon, Jean Paul, Vervaet, Chris, De Beer, Thomas
Over the last decade, there has been increased interest in the application of twin screw granulation as a continuous wet granulation technique for pharmaceutical drug formulations. However, the mixing of granulation liquid and powder material during the short residence time inside the screw...
-
Using residence time distribution in pharmaceutical solid dose manufacturing–A critical review
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Bhalode, Pooja, Tian, Huayu Gupta, Shashwat Razavi, Sonia M Roman-Ospino, Andres Talebian, Shahrzad Singh, Ravendra Scicolone, James V Muzzio, Fernando J, Ierapetritou, Marianthi
While continuous manufacturing (CM) of pharmaceutical solid-based drug products has been shown to be advantageous for improving the product quality and process efficiency in alignment with FDA’s support of the quality-by-design paradigm (Lee, 2015; Ierapetritou et al., 2016; Plumb, 2005; Schaber,...
-
Use of the channel fill level in defining a design space for twin screw wet granulation
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Gorringe, L. J., Kee, G. S., Saleh, M. F., Fa, N. H., Elkes, R. G.
Twin screw wet granulation is a key process in the continuous manufacture of oral solid dosage forms. Previous Research Article has qualitatively suggested that the channel fill level influences the granules produced. In this paper a quantitative measure of the total volumetric fraction of the...
-
TPLS as predictive platform for twin-screw wet granulation process and formulation development
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Ryckaert, A., Van Hauwermeiren, D., Dhondt, J., De Man, A., Funke, A., Djuric, D., Vervaet, C., Nopens, I., De Beer, T.
In recent years, the interest in continuous manufacturing techniques, such as twin-screw wet granulation, has increased. However, the understanding of the influence of the combination of raw material properties and process settings upon the granule quality attributes is still limited. In this...
-
Transfer from High-Shear Batch to Continuous Twin Screw Wet Granulation: A Case Study in Understanding the Relationship Between Process Parameters and Product Quality Attributes
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Beer, Paul, Wilson, David, Huang, Zhenyu, De Matas, Marcel
A twin screw to high-shear batch granulation technology switch was evaluated for a pharmaceutical development project. Differences in granule (particle size distribution and porosity) and tablet (dissolution) quality attributes were analysed for both continuous and batch technologies. Liquid to...
-
Twin screw granulation - review of current progress
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Thompson, M. R.
Twin screw granulation (TSG) is a new process of interest to the pharmaceutical community that can continuously wet granulate powders, doing so at lower liquid concentrations and with better product consistency than found by a high shear batch mixer. A considerable body of Research Article has...
-
The scope of PAT in real-time advanced control of tablet quality
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Singh, Ravendra, Ierapetritou, Marianthi, Ramachandran, Rohit
Continuous pharmaceutical manufacturing together with process analytical technology (PAT) provides a suitable platform for automatic feed-forward/feed-back (FF/FB) control of the end product quality as desired by quality by design (QbD)-based efficient manufacturing. The precise control of the...
-
The optimization of process analytical technology for the inline quantification of multiple drugs in fixed dose combinations during continuous processing
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Dadou, SM, Tian, YWLi, S, Jones, DS, Andrews, GP
Complications associated with uncontrolled hypertension are considered the major cause of premature death worldwide. Fixed-dose combinations (FDCs) offer an alternative approach to polypharmacy with the aim to improve patient compliance. Process Analytical Technology (PAT) is gaining momentum as...
-
The Use of PAT and Off-line Methods for Monitoring of Roller Compacted Ribbon and Granule Properties with a View to Continuous Processing
09 Jun 2023 | Peer-reviewed journal | Contributor(s): McAuliffe M.A.P., Omahony G.E., Blackshields C.A., Collins J.A., Egan D.P., Kiernan L., Oneill E., Lenihan S., Walker G.M., Crean A.M.
Real-time process monitoring using process analytical technology (PAT) tools can augment process understanding, enable improved process control, and hence facilitate the production of high-quality pharmaceutical products. While beneficial for batch processes, the availability of PAT tools to...
-
The Influence of Equipment Design and Process Parameters on Granule Breakage in a Semi-Continuous Fluid Bed Dryer after Continuous Twin-Screw Wet Granulation
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Ryckaert, Alexander, Ghijs, Michael, Portier, Christoph, Djuric, Dejan, Funke, Adrian, Vervaet, Chris, De Beer, Thomas
The drying unit of a continuous from-powder-to-tablet manufacturing line based on twin-screw granulation (TSG) is a crucial intermediate process step to achieve the desired tablet quality. Understanding the size reduction of pharmaceutical granules before, during, and after the fluid bed drying...
-
The development of an inline Raman spectroscopic analysis method as a quality control tool for hot melt extruded ramipril fixed-dose combination products
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Andres, G.P., Jones D.S., Senta-Loys Z., Almajaan A., Li S., Chevallier O., Elliot C., Healy A.M., Kelleher J.F., Madi A.M., Gilvary G.C., Tian Y.a
Currently in the pharmaceutical industry, continuous manufacturing is an area of significant interest. In particular, hot-melt extrusion (HME) offers many advantages and has been shown to significantly reduce the number of processing steps relative to a conventional product manufacturing line. To...
-
The effect of screw configuration and formulation variables on liquid requirements and granule quality in a continuous twin screw wet granulation process
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Vandevivere, L., Van Wijmeersch, E., Hausler, O., De Beer, T., Vervaet, C., Vanhoorne, V.
The effect of two screw configurations with varying stagger angle was evaluated on the liquid amount required to produce good quality granules for a highly (mannitol-based) and a poorly (DCP-based) soluble formulation containing different binders. It is generally known that the use of a higher...
-
The impact of channel fill level on internal forces during continuous twin screw wet granulation
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Torrecillas, Carlota Mendez, Gorringe, Lee J., Rajoub, Nazer, Robertson, John, Elkes, Richard G., Lamprou, Dimitrios A., Halbert, Gavin W
The forces experienced by the particles inside a twin screw granulator (TSG) are one of the most difficult parameters to measure quantitatively. However, it is possible to perform accurately this measurement through the use of dye containing calibrated microencapsulated sensors (LAMES) whose...
-
The Current Scientific and Regulatory Landscape in Advancing Integrated Continuous Biopharmaceutical Manufacturing
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Adam C Fisher, Mark-Henry Kamga, Cyrus Agarabi, Kurt Brorson, Sau L Lee, Seongkyu Yoon
There is a trend across the pharmaceutical sector toward process intensification and continuous manufacturing to produce small-molecule drugs or biotechnology products. For biotechnology products, advancing the manufacturing technology behind upstream and downstream processes has the potential to...
-
The development and validation of a quality by design based process analytical tool for the inline quantification of Ramipril during hot-melt extrusion
09 Jun 2023 | Peer-reviewed journal | Contributor(s): Dadou, Suha, Senta-Loys, Zoe, Almajaan, Ammar, Li, Shu, Jones, David, Healy, Anne, Tian, Yiwei, Andrews, Gavin
Continuous processing is superseding conventional batch processing as a means of manufacturing within the pharmaceutical Research Article/industry. This paradigm shift has led to the implementation of Process Analytical Technology (PAT) as a semi-automatic, predictive tool offering real-time...