Skip to main content
Join CMKC members for a complimentary virtual event on December 10, 11am ET: CM MythBusters: https://bit.ly/3YXJynA. This is a fantastic opportunity to connect, collaborate, and debunk common myths about continuous manufacturing!
18.118.193.28

Resources: All

Find a resource
  1. processanalyticaltechnology x
  2. continuousprocessing x
  3. twinscrewgranulation x
  1. Critical review on the role of excipient properties in pharmaceutical powder-to-tablet continuous manufacturing

    13 Aug 2024 | Peer-reviewed journal | Contributor(s): Sara Fathollahi, Pauline H. M. Janssen, Bastiaan H. J. Dickhoff, Henderik W. Frijlink

    The pharmaceutical industry is gradually changing batch-wise manufacturing processes to continuous manufacturing processes, due to the advantages it has to offer. The final product quality and process efficiency of continuous manufacturing processes is among others impacted by the properties of...

  2. Process intensification of pharmaceutical powder blending at commercial throughputs by utilizing semi-continuous mini-blending

    13 Aug 2024 | Peer-reviewed journal | Contributor(s): Maarten Jaspers, Florian Tegel, Timo P. Roelofs, Fabian Starsich, Yunfei Li Song, Bernhard Meir, Richard Elkes, Bastiaan H.J. Dickhoff

    Process intensification involves the miniaturization of equipment while retaining process throughput and performance. The pharmaceutical industry can benefit from this approach especially during drug product development, where the availability of active pharmaceutical ingredients (API) is often...

  3. Delta-mannitol to enable continuous twin-screw granulation of a highly dosed, poorly compactable formulation

    23 Jul 2024 | Peer-reviewed journal | Contributor(s): Vanhoorne, V., Almey, R., De Beer, T., Vervaet, C.

    In current study, it was investigated if the moisture-mediated polymorphic transition from δ- to β-mannitol during twin screw granulation (TSG) also took place in high drug loaded formulations and if the specific granule morphology associated with the polymorphic transition could enable tableting...

  4. Control oriented modeling of twin-screw granulation in the ConsiGmaTM-25 production plant

    09 Jul 2024 | Peer-reviewed journal | Contributor(s): Johannes Khinast, Martin Horn, Jakob Rehrl, Selma Celikovic, Johannes Poms

    ConsiGmaTM-25 is a continuous production plant integrating a twin-screw granulation, fluid bed drying, granule conditioning, and a tableting unit. The particle size distribution (PSD), active pharmaceutical ingredient (API) content, and liquid content of wet granules after twin-screw...

  5. Development of a Continuous Flow Grignard Reaction to Manufacture a Key Intermediate of Ipatasertib

    25 Jun 2024 | Peer-reviewed journal | Contributor(s): Kaldre, Dainis, Stocker, Severin, Linder, David, Reymond, Helena, Schuster, Andreas, Lamerz, Jens, Hildbrand, Stefan, Püntener, Kurt, Berry, Malcolm, Sedelmeier, Jörg

    This article outlines the development of a continuous flow process for the manufacture of a key intermediate of the active pharmaceutical ingredient ipatasertib for the treatment of metastatic castration-resistant prostate cancer and triple-negative metastatic breast cancer. The reaction sequence...

  6. Innovation and Continuous Improvement in Pharmaceutical Manufacturing

    28 Mar 2024 | Document | Contributor(s): Ajaz Hussain (Chairperson) Raafat Fahmy (CVM), William Bargo (CVM), Robert Coleman, Robert (ORA), Elise Murphy (ORA), Frank Holcombe Jr (CDER), Chris Watts (CDER), See Lam (CDER), Jon Clark (CDER), Christopher Joneckis (CBER), John Dietrick (CDER), Diana Kolaitis (ORA), Vilayat Sayeed (CDER), Mai Huynh (CVM), Norman Schmuff (CDER), Andrew Chang (CBER)

    The PAT Team and Manufacturing Science Working Group Report: A Summary of Learning, Contributions and Proposed Next Steps for Moving towards the "Desired State" of Pharmaceutical Manufacturing in the 21st Century

  7. A Perspective on Quality by Design: A Preclinical Opportunity

    28 Mar 2024 | Document | Contributor(s): Ajaz S. Hussain

  8. A Shared Vision for Pharmaceutical Development and Manufacturing in the 21st Century: Contributions of the PAT Initiative

    28 Mar 2024 | Document | Contributor(s): Ajaz S. Hussain

  9. The Subcommittee on Process Analytical Technologies (PAT): Closing Remarks

    28 Mar 2024 | Document | Contributor(s): Ajaz S. Hussain

  10. The Process Analytical Technology Initiative: PAT and the Pharmacopeias

    28 Mar 2024 | Document | Contributor(s): Ajaz S. Hussain

    The PAT Initiative A part of the Pharmaceutical Quality for the 21st Century Initiative  PAT and the USP Opportunities for the USP to support the PAT Framework

  11. Utilizing PAT to Monitor and Control Bulk Biotech Processes

    27 Mar 2024 | Document | Contributor(s): Rick E. Cooley

    1.What is and isn’t PAT? 2.Implementing PAT in Manufacturing: What does it take? 3.Characteristics of bulk, biotech API processes 4.Why PAT? 5.Review of PAT technologies utilized 6.PAT application examples

  12. Continuous Manufacturing for Pharmaceutical Solid Dosage Forms (On-Demand)

    31 Jan 2024 | Seminars | Contributor(s): Atul Dubey, Fernando Muzzio, Gerardo Callegari, Lucy L. Botros, Ravendra Singh, James Scicolone, Andres Roman, Sonia Modarres Razavi

    Course Description: This self-paced curriculum contains fourteen self-paced modules and three recordings of live virtual education on Pharmaceutical Continuous Manufacturing (PCM). Learners will have access to the following: A recording of the introductory session covering topics such as...

  13. Visualization and understanding of the granulation liquid mixing and distribution during continuous twin screw granulation using NIR chemical imaging

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Vercruysse, Jurgen, Toiviainen, Maunu, Fonteyne, Margot, Helkimo, Niko, Ketolainen, Jarkko, Juuti, Mikko, Delaet, Urbain, Van Assche, Ivo, Remon, Jean Paul, Vervaet, Chris, De Beer, Thomas

    Over the last decade, there has been increased interest in the application of twin screw granulation as a continuous wet granulation technique for pharmaceutical drug formulations. However, the mixing of granulation liquid and powder material during the short residence time inside the screw...

  14. Using Residence Time Distributions (RTDs) to Address the Traceability of Raw Materials in Continuous Pharmaceutical Manufacturing

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Engisch, William, Muzzio, Fernando

    Continuous processing in pharmaceutical manufacturing is a relatively new approach that has generated significant attention. While it has been used for decades in other industries, showing significant advantages, the pharmaceutical industry has been slow in its adoption of continuous processing,...

  15. Use of the channel fill level in defining a design space for twin screw wet granulation

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Gorringe, L. J., Kee, G. S., Saleh, M. F., Fa, N. H., Elkes, R. G.

    Twin screw wet granulation is a key process in the continuous manufacture of oral solid dosage forms. Previous Research Article has qualitatively suggested that the channel fill level influences the granules produced. In this paper a quantitative measure of the total volumetric fraction of the...

  16. TPLS as predictive platform for twin-screw wet granulation process and formulation development

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Ryckaert, A., Van Hauwermeiren, D., Dhondt, J., De Man, A., Funke, A., Djuric, D., Vervaet, C., Nopens, I., De Beer, T.

    In recent years, the interest in continuous manufacturing techniques, such as twin-screw wet granulation, has increased. However, the understanding of the influence of the combination of raw material properties and process settings upon the granule quality attributes is still limited. In this...

  17. Transfer from High-Shear Batch to Continuous Twin Screw Wet Granulation: A Case Study in Understanding the Relationship Between Process Parameters and Product Quality Attributes

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Beer, Paul, Wilson, David, Huang, Zhenyu, De Matas, Marcel

    A twin screw to high-shear batch granulation technology switch was evaluated for a pharmaceutical development project. Differences in granule (particle size distribution and porosity) and tablet (dissolution) quality attributes were analysed for both continuous and batch technologies. Liquid to...

  18. Twin screw granulation - review of current progress

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Thompson, M. R.

    Twin screw granulation (TSG) is a new process of interest to the pharmaceutical community that can continuously wet granulate powders, doing so at lower liquid concentrations and with better product consistency than found by a high shear batch mixer. A considerable body of Research Article has...

  19. The synthesis of active pharmaceutical ingredients (APIs) using continuous flow chemistry

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Baumann, M, Baxendale, IR

    The implementation of continuous flow processing as a key enabling technology has transformed the way we conduct chemistry and has expanded our synthetic capabilities. As a result many new preparative routes have been designed towards commercially relevant drug compounds achieving more efficient...

  20. The Use of PAT and Off-line Methods for Monitoring of Roller Compacted Ribbon and Granule Properties with a View to Continuous Processing

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): McAuliffe M.A.P., Omahony G.E., Blackshields C.A., Collins J.A., Egan D.P., Kiernan L., Oneill E., Lenihan S., Walker G.M., Crean A.M.

    Real-time process monitoring using process analytical technology (PAT) tools can augment process understanding, enable improved process control, and hence facilitate the production of high-quality pharmaceutical products. While beneficial for batch processes, the availability of PAT tools to...

  21. The optimization of process analytical technology for the inline quantification of multiple drugs in fixed dose combinations during continuous processing

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Dadou, SM, Tian, YWLi, S, Jones, DS, Andrews, GP

    Complications associated with uncontrolled hypertension are considered the major cause of premature death worldwide. Fixed-dose combinations (FDCs) offer an alternative approach to polypharmacy with the aim to improve patient compliance. Process Analytical Technology (PAT) is gaining momentum as...

  22. The Use of PAT and Off-line Methods for Monitoring of Roller Compacted Ribbon and Granule Properties with a View to Continuous Processing

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): McAuliffe M.A.P., Omahony G.E., Blackshields C.A., Collins J.A., Egan D.P., Kiernan L., Oneill E., Lenihan S., Walker G.M., Crean A.M.

    Real-time process monitoring using process analytical technology (PAT) tools can augment process understanding, enable improved process control, and hence facilitate the production of high-quality pharmaceutical products. While beneficial for batch processes, the availability of PAT tools to...

  23. The Influence of Equipment Design and Process Parameters on Granule Breakage in a Semi-Continuous Fluid Bed Dryer after Continuous Twin-Screw Wet Granulation

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Ryckaert, Alexander, Ghijs, Michael, Portier, Christoph, Djuric, Dejan, Funke, Adrian, Vervaet, Chris, De Beer, Thomas

    The drying unit of a continuous from-powder-to-tablet manufacturing line based on twin-screw granulation (TSG) is a crucial intermediate process step to achieve the desired tablet quality. Understanding the size reduction of pharmaceutical granules before, during, and after the fluid bed drying...

  24. The development of an inline Raman spectroscopic analysis method as a quality control tool for hot melt extruded ramipril fixed-dose combination products

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Andres, G.P., Jones D.S., Senta-Loys Z., Almajaan A., Li S., Chevallier O., Elliot C., Healy A.M., Kelleher J.F., Madi A.M., Gilvary G.C., Tian Y.a

    Currently in the pharmaceutical industry, continuous manufacturing is an area of significant interest. In particular, hot-melt extrusion (HME) offers many advantages and has been shown to significantly reduce the number of processing steps relative to a conventional product manufacturing line. To...

  25. The effect of screw configuration and formulation variables on liquid requirements and granule quality in a continuous twin screw wet granulation process

    09 Jun 2023 | Peer-reviewed journal | Contributor(s): Vandevivere, L., Van Wijmeersch, E., Hausler, O., De Beer, T., Vervaet, C., Vanhoorne, V.

    The effect of two screw configurations with varying stagger angle was evaluated on the liquid amount required to produce good quality granules for a highly (mannitol-based) and a poorly (DCP-based) soluble formulation containing different binders. It is generally known that the use of a higher...